GuidedSMILE Compatibilities Charts and Downloads

[us_post_title tag=”h1″ align=”left” css=”%7B%22default%22%3A%7B%22font-size%22%3A%2255px%22%2C%22font-weight%22%3A%22600%22%7D%7D”]
Bone and Occlusal Planes required for planning

All cases must include a bone reduction plane, planned near the heads of the implants as learned in Design Certification. Without the reduction plane, a case cannot be designed.

[us_image image=”56713″ link=”%7B%22url%22%3A%22%22%7D”]
[us_btn label=”Download the Planes HERE” link=”%7B%22url%22%3A%22http%3A%2F%2Fguidedsmile.us%2Fwp-content%2Fuploads%2F2024%2F01%2FFlatwafer15.zip%22%2C%22target%22%3A%22_blank%22%7D” align=”center” css=”%7B%22default%22%3A%7B%22color%22%3A%22%23ffffff%22%2C%22background-color%22%3A%22%23035c96%22%2C%22margin-top%22%3A%2225px%22%2C%22margin-bottom%22%3A%2225px%22%7D%7D”]
Critical compatibility information

Please ensure the implant you want to plan is available in our Plug-In. The below tables provide the updated information to ensure that you can fully plan your case. The grids below offer different levels of item availability. We update this as we create agreements with the implant companies.

Grid 1 – Full Compatibility

These implants provide the highest level of compatibility for planning and designing your case. The implants are OEM, the MUA’s are actual files from the manufacturer so that when you pick the abutment and collar height, the prosthetic holes are exact. The sleeves are automatically chosen with defaults and must be verified for your specific guided kit, and a manufacturer Drill Sequence Report can be generated on the ‘yes’ implants.

(*drill sequence is acquired from implant company’s standard protocols)

RG - Full Compatibility

Implant Line Implant System Available? OEM MUA Available? OEM Sleeve in RealGuide Generated Drill Report
3i Yes Yes Yes Yes
Adin Yes Yes Yes *
Ankylos ND Yes Yes Yes *
Ankylos WD Yes Yes Yes *
AstraEV ND Yes Yes Yes *
AstraEV WD Yes Yes Yes *
BHI Yes Yes Yes *
BioHorizons Yes Yes Yes Yes
BioHorizons New Kit Yes Yes Yes Yes
BioTech Yes Yes Yes *
Camlog Yes Yes Yes *
Hahn Yes Yes Yes Yes
Implant Direct Legacy 1,2,3,4 Yes Yes Yes No
Implant Direct Simply Iconic Yes Yes Yes Yes
Implant Direct Simply Interactive Yes Yes Yes Yes
Implant Direct Simply Legacy 2,3 Yes Yes Yes Yes
MegaGen Yes Yes Yes *
MIS Narrow Yes Yes Yes *
MIS Seven Yes Yes Yes *
NeoBiotech Yes Yes Yes *
NeoDent EasyGuide Yes Yes Yes Yes
NeoDent GM Keyed Yes Yes Yes *
Nobel Active Yes Yes Yes Yes
Nobel Parellel CC Yes Yes Yes Yes
Nobel Replace CC Yes Yes Yes Yes
Noris Medical EZGuide Yes Yes Yes *
Paltop Yes Yes Yes *
Ritter Yes Yes Yes *
Surgikor Yes Yes Yes *
Sweden Martina N Echoplan Yes Yes Yes Yes
Sweden Martina R Yes Yes Yes Yes
Thommen Yes Yes Yes Yes
Xive ND Yes Yes Yes *
Xive WD Yes Yes Yes *
Zimmer Master A Yes Yes Yes Yes
Zimmer Master B Yes Yes Yes Yes
ZimVie Z3D OEM Yes Yes Yes Yes

Grid 2 – Partial Compatibility (simple MUA substitution)

These implants provide a very good level of compatibility for planning and designing your case. The implants are OEM, the MUA’s will be exchanged with RealGuide’s closest option called 3Diemme. The sleeves are automatically chosen with defaults and must be verified for your specific guided kit, and a manufacturer Drill Sequence Report can be generated for some and not others.

(*drill sequence is acquired from implant company’s standard protocols)

RG - Partial Compatibility

Implant Line Implant System Available? OEM MUA Available? OEM Sleeve in RealGuide Generated Drill Report
Straumann BLT Yes No - use 3Diemme Yes Yes
Straumann BLX Yes No - use 3Diemme Yes Yes
Ditron Yes No - use Zimmer No No
Hiossen Yes No Yes No
MegaGen Blue Diamond Yes No Yes No
Versah Yes No Yes No

Grid 3 –Outsource to GuidedSMILE (requires customized components, sleeve and reports)
These implants are possible with GuidedSMILE and we have made hundreds of cases. However, the software company has not been permitted the files needed for DIY activity for GuidedSMILE type cases. Please send your plan for GuidedSMILE to modify and finalize or records to begin a case. Fees change based on the amount of accurate work-up of completed prior to submission.

(*drill sequence is acquired from implant company’s standard protocols)

RG - Outsource to GuidedSMILE

Implant Line Implant System Available? OEM MUA Available? OEM Sleeve in RealGuide Generated Drill Report
BlueSkyBio BioMax No No No No
BlueSkyBio Hex No No No No
Keystone GENESIS Tilobe No No No No
Keystone Prima Connex ? No No No No
Keystone Prima Plus No No No No

Sleeveless Settings for GuidedSMILE LITE Cases

Use the below settings for sleeveless GuidedSMILE or CombiGuide LITE. Do not use these settings for metal. Metal guides should have OEM sleeves, which should be purchased from GuidedSMILE or the implant manufacturer. Notice the image labelled “Sleeve Set-Up Settings Window ” and input the below numbers and save as a name you will recognize.

RG - Sleeveless Settings for GuidedSMILE LITE Cases

Brand Kit RealGuide Label Implant Size OD - D(ext) GHD - D(int) H - L(sl) RG Offset - H(sl) Compensation - RS Total Offset
Bluesky Fully Guided Keyless BSB GS 8.5 All 5.04 4.84 5 3.5 0 8.5*, 10.5, 12.5
Hahn Hahn (keyless) Hahn 3.0 GS 3 3.55 3.35 6 3 0 12
Hahn Hahn (keyless) Hahn 3.5 GS 3.5 3.8 3.6 6 3 0 9
Hahn Hahn (keyless) Hahn 4.3 GS 4.3 5.25 5.05 6 3 0 9
Hahn Hahn (keyless) Hahn 5 GS 5 5.25 5.05 6 3 0 9
Hiossen Hiossen OneG -5 (keyless) Hiossen -5 GS < 5.0 5.05 4.85 6 4.5 0 10.5
Hiossen Hiossen OneG -5 (keyless) Hiossen 5+ GS ≥ 5.0 5.75 5.55 6 4.5 0 10.5
Megagen R2 MegaG -4.5 GS ≤ 4.5 5.05 4.85 6 6.5 0 12.5
Megagen R2 MegaG 5.0+ GS ≥ 5.0 6.5 6.3 6 6.5 0 12.5
MIS all MIS GS all 5.5 5.3 6 4.5 0 10.5
Neodent GM Easyguide (keyless) Neodent EasyG N 3.75 GS ≤ 3.75 3.88 3.68 6 4 0 10
Neodent GM Easyguide (keyless) Neodent EasyG W 4.0+ GS ≥ 4.0 5.2 5 6 4 0 10
Zimmer Z3D NA all 5 4.9 4 5 0 x